Skip to content
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
🚛 Flat Rate Shipping $17.95+ GST For Metro & standard delivery zones! Excludes remote/regional and high-cost postcodes (including parts of QLD, WA, NT & TAS), and bulky or heavy items. Online only. Learn More
11

Gripset C-Plug

Active water pouring through a concrete crack means you don't have time to wait. Gripset C-Plug sets in under a minute and hits 8 MPa in 30 minutes, so you stop the flow now and keep working. It's a non-shrink, cement-based plug built for exactly this, not a membrane that needs dry conditions first. Not for cosmetic patching or hairline cracks with no water pressure. This is for active leaks in basements, retaining walls, tanks and wet areas where water is moving through the concrete right now.
Vendor: Gripset
SKU: GRIPCPLUG/4
Availability: In Stock
$51.96
$51.96
Prices do not include GST
Shipping & Delivery

Flat-rate shipping $17.95 + GST (metro and standard zones). Excludes remote/regional/high-cost postcodes and certain items (DG, oversized, long-length, or bagged products 15 kg+). If your order includes any of these, we will contact you to arrange additional freight charges. Online purchases only.

Water actively flowing through a crack in concrete means more than just a drip; it means compromised integrity and immediate risk. Stopping that flow is the urgent priority. Gripset C-Plug delivers an instant, pressure-resistant seal, bringing active water leaks under control within minutes. This allows work to progress, securing the area for long-term waterproofing solutions.

Why this product exists

Traditional waterproofing membranes and repair mortars require dry conditions to perform. When water is actively flowing, these products are ineffective, leaving structures vulnerable to ongoing damage. Gripset C-Plug was engineered for these precise situations. It arrests active water leaks and seals openings in concrete and masonry surfaces where conventional methods fail, providing a critical first step to secure a compromised area.

This cement-based compound forms a non-shrink, high-compressive-strength plug that withstands ongoing water pressure. It is specifically designed to stop leaks under duress, preventing cascading damage and structural compromises that result from unchecked water ingress.

The numbers that matter

  • Rapid Set Time: With an initial set in less than 1 minute and a final set within 2-4 minutes, Gripset C-Plug immediately halts water flow. This rapid action minimises downtime and prevents further water damage, allowing follow-up work to begin quickly.
  • Compressive Strength: It achieves 8 MPa of compressive strength in just 30 minutes, escalating to 35 MPa after 28 days. This ensures the plug is not just a temporary barrier but a robust, structurally sound repair that can resist significant water pressure over time.
  • Non-Shrink Formulation: This compound does not shrink as it cures, creating a tight, permanent seal that maintains contact with the substrate. This prevents new pathways for water to exploit around the repair, enhancing the overall integrity of the fix.
  • Reinforcement Safe: Gripset C-Plug is formulated not to promote corrosion of steel reinforcement. This is critical for concrete structures, ensuring the repair does not inadvertently weaken the embedded steel components over the long term.

What it's like to use

Using Gripset C-Plug requires precise and rapid execution due to its fast-setting nature. Prepare the surface by grinding cracks or holes to a minimum 20mm width and depth, ensuring a square or dovetail profile, not a 'V' shape. This creates a mechanical key for maximum adhesion. Flush the area to remove loose debris, then dampen the surface with clean water just before application.

Mix Gripset C-Plug by hand, in small batches (approximately 0.5kg), using around 150ml of water per kilogram of powder. Avoid electric stirrers; mix quickly with a spatula to a paste or putty consistency. Once a slight warmth is felt or setting begins, immediately press the material firmly into the opening. Maintain pressure until set, then slowly release. For larger areas, work from the outside in. After setting, dampen the plug with water for 15 minutes to aid curing.

Where this product excels

  • Basement and Cellar Leaks: When active leaks appear in subterranean structures like basements, cellars, or lift shafts, Gripset C-Plug instantly stops the water, preventing further damage and preparing the surface for a full waterproofing system.
  • Water Retaining Structures: For water tanks or concrete retention structures, it provides an immediate fix for cracks or holes, sealing leaks under pressure without the need to fully drain the structure in all cases.
  • Civil Infrastructure Repairs: In tunnels, culverts, or sewer systems, this rapid-setting plug can seal leaking joints or cracks in concrete segments, minimising disruption and providing a durable repair in challenging, wet environments.
  • Anchoring in Wet Conditions: It excels at rapid-set anchoring of bolts, fixtures, and pipes into primed or dense concrete, even in damp conditions, offering a quick and secure hold where other anchors might struggle.

How it fits in a real system

Gripset C-Plug serves as the crucial first step in a comprehensive waterproofing strategy when active water ingress is present. It is designed to halt the immediate problem, creating a dry and stable substrate. Once the leak is stopped and the C-Plug has cured, it prepares the surface for the application of a long-term waterproofing membrane. For enduring protection against future dampness and seepage, the set Gripset C-Plug is typically covered with a flexible cementitious membrane like Gripset C-1P.

Choose this when

  • When water is actively flowing through cracks or holes in concrete or masonry and requires an immediate stop.
  • For urgent repairs in basements, lift pits, water tanks, or tunnels where rapid sealing is critical.
  • When needing to create a waterproof, pressure-resistant fillet at wall/floor junctions in water-retaining structures, prior to membrane application.
  • For rapid-set anchoring of equipment or fixtures into concrete surfaces where a quick, strong hold is necessary, even in damp conditions.

Don't use this when

  • Not for: Expansion or movement joints. Its rigid, non-shrink nature makes it unsuitable for areas requiring flexibility. Consider a flexible joint sealant for these applications.
  • Not for: Non-cementitious surfaces. This product is formulated for concrete and masonry.
  • Not for: Frozen surfaces. Ensure surfaces are free of ice for proper adhesion and curing.

Frequently asked questions

How quickly does Gripset C-PLUG set?

Gripset C-PLUG begins setting in 30–60 seconds, with a final set in 2–4 minutes. This rapid action is critical for stopping active water flow and working under pressure.

Can Gripset C-PLUG stop active water leaks under pressure?

Yes, Gripset C-PLUG is specifically designed for active leak sealing, forming an instant waterproof barrier against hydrostatic pressure. Prepare the substrate with square or dovetail edges and dampen before application.

Is Gripset C-PLUG safe for drinking water tanks?

Yes, the formulation is non-toxic, non-staining, and odour-free. This makes it suitable for sealing leaks in potable water storage structures without contamination.

Can Gripset C-PLUG be used on non-concrete surfaces?

No, Gripset C-PLUG is formulated for concrete and masonry substrates only. For non-cementitious materials like metal, plastic, or timber, a different product is required.

How should Gripset C-PLUG be mixed?

Gripset C-PLUG must be hand mixed only to achieve the correct set times. Avoid using electric mixers or paddle stirrers, as these can accelerate the set beyond the working window.

Applications and benefits

Where Gripset C-PLUG is used, what it delivers, and who uses it
Application Key benefit Primary trades
Sealing active water leaks in concrete and masonry Forms an instant, high-strength waterproof barrier against hydrostatic pressure in under 60 seconds. Waterproofers, Builders, Civil Contractors
Leak repair in water tanks and retention structures Non-toxic and non-staining formulation is safe for potable water storage applications. Waterproofers, Civil Contractors
Stopping leaks in basements, cellars, and lift pits Arrests water ingress quickly, preventing further structural damage in negative water pressure conditions. Waterproofers, Builders
Repairing concrete pipes, culverts, and tunnels Creates pressure-resistant seals, maintaining integrity in submerged and high-flow underground environments. Civil Contractors, Plumbers
Forming fillets at wall/floor junctions in water-retaining structures Creates durable, rigid coves that enhance the performance of subsequent waterproofing membranes. Waterproofers, Builders
Anchoring bolts, fixtures, and conduits in damp concrete Provides rapid, structural grip and secure embedment even on saturated substrates. Builders, Plumbers, Electrical Contractors

Applying Gripset C-PLUG: Enhanced Protocols & Best Practices

  1. Surface Preparation

    Remove loose material, laitance, de-bonded coatings, curing agents, release agents, waxes, oils/grease, moss and grime. Flush with clean water to remove fines and leave the substrate damp (no standing water).

    Chasing/Grinding Cracks & Holes

    Chase to a minimum 20 mm width and depth with square or dovetail edges. For high-volume leaks, increase depth to ≥40 mm. Avoid V-shaped profiles. Leave a rough mechanical key.

    Junctions & Fillets

    At wall/floor junctions, chase the joint to at least 20 mm and slightly back into the wall. After sealing, form a ~45° cove ~40 mm wide where required.

    Timing: Complete cutting and flushing immediately before mixing to maintain a damp, clean substrate.
    Pro Tip: Work from the outside toward the centre of larger leak areas to progressively control active water flow.
  2. Mixing

    Mix by hand only to a stiff paste/putty. Prepare small batches you can place within ~1 minute.

    Water Ratio & Temperature

    As a guide, use ~150 mL of water per 1 kg of powder. Use mixing water at approximately 20 °C to enable correct strength development.

    Batch Size & Technique

    Limit each batch to about one handful (~0.5 kg). Place powder into a clean pail, add water, and mix quickly with a spatula until uniform. Hold the mix in a gloved hand until warmth or signs of initial set are felt.

    Timing: Initial set begins in ~30–60 seconds; final set occurs in ~2–4 minutes.
    Pro Tip: Do not use electric stirrers or paddle mixers—hand mixing preserves the rapid set profile and correct consistency.
  3. Placement & Sealing

    Press the mixed compound firmly into the opening, maintaining constant hand pressure until initial set.

    Active Leak Control

    Seat the plug against the direction of water flow. Maintain pressure for ~30–60 seconds until the material locks. Remove your hand gradually.

    Large/Open Areas

    For larger defects, place multiple small plugs, working outside-in until the area is fully sealed.

    Timing: Initial set typically achieved in under 1 minute. Full set in 2–4 minutes.
    Pro Tip: Keep a second batch staged (dry powder measured) if the leak rate is high so you can mix and place immediately after the first plug sets.
  4. Curing & Finishing

    Once the plug has set, lightly re-dampen to support early hydration, then dress to profile.

    Moist Curing

    After final set, mist or sponge with clean water for ~15 minutes.

    Shaping

    When hardened, the plug can be sanded or ground to match existing structural contours.

    Timing: Begin light finishing after full set (approx. 2–4 minutes). Delay aggressive grinding until sufficient hardening has developed.
    Pro Tip: If ambient temperatures are low, expect slower curing. Using slightly warmer mix water can help maintain normal set times.
  5. Overcoating / System Integration

    For long-term dampness and seepage control (negative-side), integrate with the Gripset waterproofing system.

    Membrane Overcoat

    Once leaks are sealed and the plug has set, overcoat with Gripset C-1P flexible cementitious membrane according to membrane TDS guidance.

    Detailing at Junctions

    Form the 45° cove before membrane application to reduce stress concentration and improve waterproofing continuity.

    Timing: Apply the membrane after the plug has fully set and surface moisture has stabilised.
    Pro Tip: Plan your sequence so membrane coverage occurs the same day the leaks are controlled to minimise re-wetting risk in subterranean areas.
  6. Environmental & Application Conditions

    Apply to damp (not flooded) cementitious substrates only. Avoid frozen surfaces and remove ice where freezing conditions exist.

    Temperature Considerations

    Cold ambient conditions slow curing. Slightly warm mix water may help maintain set times. Store product off concrete floors and out of direct sun.

    Incompatibilities

    Do not use over non-cementitious surfaces or as a sealant/filler for expansion/movement joints.

    Timing: Plan short mixing/placement cycles to align with the sub-1-minute initial set.
    Pro Tip: Stage tools, water, and measured powder within arm’s reach before mixing to execute a continuous placement.

Product limitations

  • Not for: Use over non-cementitious substrates such as metal, plastic, or timber. This product is formulated for concrete and masonry only.
  • Not for: Use as a sealant or filler for expansion or movement joints. The rigid set will not accommodate structural movement.
  • Not for: Application over frozen or ice-covered surfaces. Surfaces must be free from ice prior to placement to ensure proper bond and set.
  • Mixing: Do not use electric mixers or paddle stirrers. Hand mixing is required to control the rapid set time and ensure correct placement.

Safety and handling

Personal protective equipment

Wear impervious gloves (e.g., nitrile), safety goggles or a face shield, and protective clothing to prevent skin or eye contact. Use a dust mask (P2/P3) during mixing to avoid inhaling cement dust.

Ventilation

Use in well-ventilated areas. Although non-toxic and odour-free, cement dust can be harmful if inhaled. Ensure adequate airflow, especially in enclosed spaces like basements or tunnels.

First aid

  • Eyes: Flush immediately with clean water for at least 15 minutes. Seek medical advice if irritation persists.
  • Skin: Wash thoroughly with soap and water. Remove contaminated clothing. Seek medical attention if irritation develops.
  • Inhaled: Move to fresh air. Seek medical advice if coughing or breathing difficulties occur.
  • Swallowed: Rinse mouth. Do not induce vomiting. Seek immediate medical attention.

Storage and disposal

Store in sealed pails in a dry environment, protected from moisture ingress. Avoid direct sunlight or storage on bare concrete floors to prevent premature hardening. Dispose of waste according to local regulations.

Substrate guide

Correct substrate preparation is crucial for Gripset C-PLUG to achieve maximum bond and immediate leak arrestment.

Concrete

Surface prep: Remove all loose material, coatings, and contaminants. Chase cracks or holes to a minimum 20 mm width and depth, ensuring square or dovetail edges to create a mechanical key. Flush thoroughly with clean water to remove fines. Dampen the area before application, ensuring no standing water.

Primer: Not required. The product bonds directly to sound, pre-dampened concrete.

Masonry (Brick/Block)

Surface prep: Chase leaking joints or cracks to at least 20 mm, squaring the sides where possible. Remove dust and contaminants, then flush and dampen. Maintain a rough profile for mechanical keying.

Primer: Not required. Pre-dampen porous masonry to prevent rapid water suction and ensure proper bond development.

Wall/Floor Junctions

Surface prep: Cut out the joint or crack to a minimum 20 mm width, chasing slightly into the wall for a secure fit. Clean thoroughly, flush to remove dust, and dampen. After plugging, a ~45° cove approximately 40 mm wide can be formed for water-retaining structures.

Primer: Not required. For long-term waterproofing, overcoat with Gripset C-1P flexible cementitious membrane once the plug has set and cured.

Concrete Pipes, Culverts, Tunnels

Surface prep: Grind or chase leaking joints or holes to at least 20 mm; for high-volume leaks, increase to ≥40 mm. Clean, flush, and dampen before placement. For larger areas with active flow, work from the outside toward the centre.

Primer: Not required. Once sealed and set, the product can be sanded or ground to match existing contours.

Dense / Previously Primed Concrete

Surface prep: Remove any release agents, curing compounds, coatings, or primers that could inhibit bond. Mechanically roughen the surface to expose sound concrete, flush thoroughly, then dampen before application. Bond relies on a clean, roughened, pre-dampened surface.

Primer: Not required. Do not apply over incompatible or delaminating coatings.

Gripset C-Plug Physical Properties

Gripset C-Plug Physical Properties
Property Value
Appearance Grey powder
Density 2150 kg/m³
Tensile Strength 3.0 N/2 mm
Compressive Strength 35 MPa
Trafficable Time 2–4 minutes
Optimal Application Temperature Approximately 20°C
Mixing Ratio (Water:Powder) 150 mL per 1 kg
Packaging 4 kg and 15 kg bags (in pails)
Shelf Life 12 months (dry storage)

Gripset C-Plug - Use Cases

Here are some common examples on where Gripset C-Plug used by our customers.

Civil Construction

Stop Active Concrete Water Leaks

When water is actively flowing through cracks, holes, or joints in concrete and masonry infrastructure.

Its rapid set creates an instant, non-shrink, waterproof seal under pressure, quickly halting leaks and curing to high mechanical strength.

  • Initial set <1 minute
  • 35 MPa compressive strength
  • Concrete, masonry surfaces
  • Non-shrink formulation

Waterproofing

Waterproof Wall-Floor Junction Fillets

Creating pressure-resistant coves at wall/floor junctions in water tanks, basements, or other water-retaining structures.

Forms durable, non-corrosive fillets with high mechanical strength, integrating with flexible membranes for long-term seepage protection.

  • Use with Gripset C-1P
  • Non-corrosive to steel
  • 3.0 N/2mm tensile strength
  • Water-retaining structures

Civil Construction

Rapid Anchoring into Concrete

Securely anchoring bolts, fixtures, conduits, or sanitary equipment into primed or dense concrete surfaces.

Achieves instant, high-strength mechanical anchorage without shrinkage or steel corrosion, ensuring fast and reliable fixture installation.

  • Final set 2-4 minutes
  • 8 MPa @ 30 mins
  • Dense concrete substrate
  • Does not promote corrosion

Alternative Products

Need Help with Gripset C-Plug?

Need more information about this product? Hit the button below and reach out to one of our experts now.

Recently Viewed Products

Thanks for subscribing!

This email has been registered!

Shop the look
Choose Options
Edit Option
Compare
Product SKUDescription Collection Availability Product Type Other Details
this is just a warning
Login
Shopping Cart
0 items